In this blog post, we’ll explore the principles behind using ESS to bridge the time gap between the production and consumption of renewable energy and using smart grids to regulate the flow of electricity. We’ll also examine the optimal scale and economic viability of power generation facilities and storage systems using a school power grid as a case study.
- ESS enables renewable energy to be used when needed
- Smart Grids Coordinate Generation, Storage, and Consumption
- The scale of a school’s power generation facilities is determined based on weather and electricity usage data.
- To determine the optimal ESS capacity, both storage capacity and output must be considered
- Economic efficiency is determined by the amount of savings on electricity bills and total operating costs.
- While falling ESS prices improve economic viability, the optimal scale changes
ESS enables renewable energy to be used when needed
The times when solar power generation is high do not always coincide with peak electricity consumption. In schools, for example, solar power is generated even on sunny holidays, but electricity usage in classrooms and cafeterias may be lower than on school days. Similarly, with wind power, the times when the wind blows and when electricity is needed differ. To utilize renewable energy efficiently, it is essential to consider not only how much electricity is generated but also when that electricity can be used.
An Energy Storage System (ESS) serves to bridge this time gap. It stores energy when there is a surplus and supplies it when generation is insufficient or electricity demand is high. While there are various storage technologies for ESS, this section focuses on battery-based ESS systems that can be integrated with renewable energy facilities in buildings or schools.
However, it is not possible to retrieve and use all the electricity stored in an ESS. Energy losses occur during the charging, discharging, and power conversion processes. Therefore, if the generated electricity can be used immediately where it is needed, there is little reason to go through the storage process unnecessarily. The value of an ESS lies not in the storage itself, but in shifting electricity—which would otherwise be difficult to utilize—to the times when it is needed.
ESS is not the only way to respond to fluctuations in solar and wind power generation. Other methods—such as reinforcing the power grid, increasing interregional power exchange, and adjusting consumption times to match supply conditions—can be utilized in conjunction with ESS. By combining with these measures, ESS enhances the flexibility needed to balance power supply and demand.
Smart Grids Coordinate Generation, Storage, and Consumption
A smart grid is an intelligent power grid that integrates information and communication technology (ICT) and digital control technology into the existing power grid. It monitors power generation, electricity consumption, and the status of the grid, and adjusts power production and consumption accordingly. While an ESS is a device that stores energy, a smart grid can be viewed as the infrastructure that exchanges information and controls various facilities—including storage devices—to ensure they operate appropriately based on the situation.
This concept must be distinguished from distributed energy. Installing power generation facilities near locations where electricity is consumed—such as schools or buildings—constitutes a distributed power supply model. These generation facilities and ESS units can be utilized as distributed energy resources, and the smart grid plays the role of integrating and operating these resources in conjunction with the existing power grid. Simply installing solar panels and batteries at a school does not automatically optimize the flow of electricity.
For example, a school’s energy management system can simultaneously monitor solar power generation, electricity demand in classrooms, remaining battery capacity, and applicable rates. The system allows the school to use generated electricity immediately, store surplus power in anticipation of future demand, and supply power from the battery when needed. It is also possible to shift the operating hours of adjustable equipment to times when power generation is high. When this type of operation is integrated with the power grid, it helps increase the utilization of renewable energy while reducing the phenomenon of peak power demand at specific times.
The scale of a school’s power generation facilities is determined based on weather and electricity usage data.
To analyze the economic viability of power generation facilities and ESS, one must first calculate how much electricity can be generated at that location and how much of that electricity can be utilized. When targeting schools, it is necessary to examine differences in electricity usage by time of day, as well as variations between weekdays and weekends, the academic year and vacation periods, and periods when heating and cooling are in use. Even among schools with the same annual electricity consumption, the appropriate size of the power generation system and ESS may vary depending on when the electricity is used.
When estimating solar power generation, factors such as solar radiation, the orientation and tilt of the panels, surrounding shade, temperature, and system losses are taken into account. Wind power generation is calculated using wind speed data from the installation site and the power output curve for each turbine. The power output curve shows how much power a turbine generates at different wind speeds.
Wind turbines generally do not generate power when the wind is very light but begin generating power once a certain wind speed is reached. As wind speed increases, output also increases; depending on the design, output may be limited or adjusted near the rated output. When the wind is excessively strong, output may be reduced or operation halted to protect the equipment. Specific operating ranges and control methods vary by model.
For this reason, it is difficult to estimate annual power generation based solely on average wind speed. Even with the same average wind speed, power generation can differ between a location where wind suitable for power generation blows consistently and a location where light and strong winds alternate. Even within the same region, such as Incheon, wind conditions vary depending on the actual installation height, surrounding buildings, and topography; therefore, analysis must be based on the specific location where the generator will be installed.
When comparing generators with rated outputs of 20 kW, 30 kW, and 50 kW, economic viability cannot be determined based solely on output size. Rated output refers to the power that can be generated under specified conditions; it does not mean that power will be generated at that level continuously throughout the year. The expected power generation of each model must be compared alongside installation and maintenance costs. While one year’s worth of hourly weather data can be used for a preliminary analysis, evaluating long-term project viability requires reviewing data spanning multiple years to account for annual variations in weather conditions.
To determine the optimal ESS capacity, both storage capacity and output must be considered
When designing an ESS, it is important to distinguish between storage capacity and charge/discharge power. The unit of storage capacity, kWh, indicates how much energy can be stored, while the unit of power, kW, indicates how much power can be supplied or received at any given time. Even with the same storage capacity, if the power output is low, the system may not be able to adequately handle concentrated power demand over a short period.
For example, an ESS with 100 kWh of available energy and a discharge power of 50 kW can supply 50 kW of power for approximately 2 hours, assuming no losses. In actual operation, however, conversion losses and the operating range required for battery protection must be taken into account. This is why one should not judge how long an ESS can supply power to an entire school based solely on its storage capacity.
The basic method for determining the appropriate scale is to set up various combinations of power generation facilities and ESS, and then calculate the charging and discharging processes based on hourly generation and consumption. By comparing the amount of power purchased from the grid, the surplus power, electricity rates, and equipment costs for each combination, one can identify the most economical scale. While it is possible to first determine the scale of the power generation facilities and then evaluate the ESS, comparing the scales and operating modes of both systems together increases the likelihood of finding a more advantageous combination.
If the ESS is too small, it may not be able to sufficiently store surplus renewable energy. However, if the surplus power can be fed into the grid, it is not entirely wasted; its value varies depending on sales or settlement terms. Conversely, installing an ESS that is excessively large may result in underutilization of the added storage capacity, leading to a higher investment burden. If the goal is economic efficiency, the option of not installing an ESS should also be included in the comparison.
Economic efficiency is determined by the amount of savings on electricity bills and total operating costs.
Installing renewable energy facilities reduces the amount of electricity purchased from the grid. In addition, an ESS can help shift the timing of electricity purchases or reduce peak power demand. Under contracts with time-of-use rate differentials, it may be advantageous to charge during relatively inexpensive hours and discharge during expensive hours; under contracts where peak demand is factored into the rate, costs can be reduced by supplying battery power during peak demand periods.
These effects vary depending on the actual rate plan. When analyzing schools in Korea, it is essential to verify each school’s electricity service contract and the applicable rates. If the difference in rates between charging and discharging is small, the expected cost savings may not materialize due to energy losses and the costs associated with battery usage.
Furthermore, the total savings achieved by installing both power generation equipment and an ESS together should not be attributed solely to the ESS. To distinguish the additional benefits generated by the storage system, one must compare the scenario where only power generation equipment is installed with the scenario where an ESS is added. It is only economically viable if the value of the additional savings exceeds the cost of adding the ESS.
The payback period is a basic indicator for evaluating this. Assuming the annual net savings remain constant, the simple payback period can be calculated by dividing the initial investment cost by the annual net savings. Here, net savings refer to the amount remaining after subtracting operating and maintenance costs from the electricity bill savings and corresponding revenue.
However, the payback period alone cannot fully explain long-term economic viability. Batteries degrade in storage performance over time as they undergo repeated charging and discharging cycles, and replacement costs may arise. Costs for power conversion devices, control systems, installation work, safety equipment, and grid interconnection must also be included. In long-term analysis, it is necessary to discount future costs and benefits to present value to determine whether the investment is worthwhile over the entire lifespan of the facility.
While falling ESS prices improve economic viability, the optimal scale changes
The declining costs of battery storage systems are creating favorable conditions for combining renewable energy with ESS. According to the report “Renewable Power Generation Costs in 2024” published in 2025 by the International Renewable Energy Agency (IRENA), the total installation cost of large-scale battery storage projects worldwide fell by approximately 93%, from $2,571 per kWh in 2010 to $192 per kWh in 2024.
This figure reflects global cost trends for large-scale projects. It does not directly apply to estimates for small-scale ESS installations in South Korean schools, as the installation scale, location, construction conditions, and included equipment and cost items vary. In actual analysis, a distinction must be made between the price of the batteries themselves and the total system cost after installation and commissioning.
All other things being equal, as ESS prices fall, the burden of initial investment costs decreases, and larger storage capacities are more likely to become an economical choice. However, if there is insufficient surplus electricity to store or insufficient future electricity demand, there is little reason to increase capacity even if batteries become cheaper. Price declines do not guarantee the same payback period or cost savings in every location.
The key to utilizing ESS and smart grids lies in coordinating power generation, storage, and consumption within a single system. By determining the scale of the facilities based on the school’s actual electricity usage patterns and local weather conditions, and by operating the system in accordance with electricity rates and battery status, it is possible to simultaneously increase both the utilization of renewable energy and economic efficiency. Rather than focusing on the size of the power generation facilities and storage devices to be installed, it is more important to consider how to design and operate the system to supply the necessary electricity at the appropriate times.