Microfluidics: Principles and Structures of Miniature Devices for Cell Culture

In this blog post, we will examine the basic principles of microfluidics, as well as the structure and fabrication methods of microfluidic devices, and explore how the technology for controlling the flow of tiny fluids is applied to cell culture, neuroscience and vascular research, and tissue engineering.

 

Introduction

The 1966 film ‘The Micro-Commando’ features a scene in which people—whose bodies and submarines have been miniaturized—enter a scientist’s body to remove a blood clot. The idea of navigating through blood vessels to treat the body remains fascinating even today. In fact, research has been conducted to create tiny swimming devices propelled by the power of living cells. In 2014, a research team—including the University of Illinois at Urbana-Champaign—announced a device in which cardiac muscle cells were cultured on a flexible polymer tail; the cells’ contractions caused the tail to bend, propelling the device forward through a liquid.
To understand such devices, one must know how movement in water changes as size decreases. This is because simply scaling down a visible submarine does not mean it will move in the same way. Microfluidics is the field that seeks to understand the properties of fluids in such small spaces and precisely control their flow. In biology, this principle is used to create environments for cells to live in within small chips and to observe their growth and responses.

 

Water Flow Changes in Small Channels

To understand microfluidics, imagine a reservoir and a waterway. By filling the reservoir with water and adjusting the sluice gate, you can direct water to a desired location or change the water level. Microfluidic devices are similar in that they connect small reservoirs and channels to control the movement of liquids. However, when the width or height of these channels shrinks to the micrometer scale, properties that were not prominent in large reservoirs become significant. One micrometer (μm) is one-millionth of a meter, or 10⁻⁶ m. A fluid refers to a substance capable of flowing, such as a liquid or a gas, and cell culture devices primarily handle liquids like culture media.
The Reynolds number is an indicator that explains these size-dependent differences. The Reynolds number compares the effect of inertia, which tends to maintain motion, with the effect of viscosity, which impedes flow, and is expressed as follows:

Re = ρvL/μ

Here, ρ is the density of the fluid, v is the typical flow velocity, L is the characteristic length representing the scale of the flow, and μ is the viscosity coefficient. When calculating flow within a channel, the average flow velocity is used, and the “hydraulic diameter” of the channel is sometimes employed as the characteristic length. The hydraulic diameter is calculated by dividing four times the cross-sectional area through which the fluid flows by the circumference of the wall in contact with the fluid. If the same fluid flows at the same velocity, the Reynolds number decreases as the channel becomes smaller, and the effect of viscosity becomes greater relative to inertia.
However, this does not mean that water entering a small channel actually becomes as sticky as mud in a tidal flat. It is not that the viscosity of water suddenly increases, but rather that the proportion of viscosity in the motion of small objects becomes larger. In environments with very low Reynolds numbers, an object that has stopped propelling itself cannot travel far due to inertia. Furthermore, since it is difficult to move forward through simple back-and-forth motion that merely reverses the same action, methods such as creating wave-like deformations in a flexible tail or rotating a helical structure are useful. In other words, rather than relying on a small propeller getting tangled in the water to stop, one must design a propulsion principle suited to the object’s size.
In many microfluidic devices used for cell culture, “laminar flow”—where liquids flow in distinct layers rather than being vigorously mixed—occurs. Even two solutions flowing side by side gradually mix through diffusion, as molecules spread across their interface. Researchers can utilize this property to create varying concentrations of substances around cells depending on their location. Thus, the flow characteristics observed on a small scale become a means of regulating the cellular environment.

 

From a Cell-Holding Vessel to a Device for Designing the Cellular Environment

When cells are placed in a small space—which acts as a reservoir—and culture medium is supplied through channels—which act as waterways—the microfluidic device becomes a cell culture system. The culture medium is a liquid containing nutrients, salts, and other substances necessary for cell survival. Researchers can control what, how much, and when to supply to the cells by adjusting the shape of the channels and the flow rate. Although the use of samples and reagents can be reduced in small culture spaces, the actual cost must be calculated by considering not only the device itself but also peripheral equipment such as pumps.
A key advantage of this technology is the ability to finely adjust the environment in which cells are placed, both spatially and temporally. For example, by supplying growth factors—which influence cell growth or migration—from one side, a “concentration gradient” can be created, where the concentration is high near the source and low farther away. Within this environment, researchers can observe which direction the cells move and under what conditions they survive best. It is also possible to administer fluorescent labels or drugs at specific times and track the response under a microscope, or to analyze the effluent culture medium to investigate substances secreted by the cells.
The ability to configure the culture space in three dimensions is also important. In conventional two-dimensional culture, many animal cells adhere to the bottom of the culture vessel and grow there. This property, requiring a surface to which they can attach, is called “adhesion-dependent.” However, not all normal animal cells must necessarily adhere to the bottom. Since some cells, such as hematopoietic cells, grow while suspended in the culture medium, adhesion status alone cannot be used to distinguish between normal and cancer cells.
In three-dimensional culture, cells can be placed inside a hydrogel—a material with a mesh-like structure that retains a large amount of water. Gels made from materials such as collagen mimic some of the properties of the “extracellular matrix,” which supports cells within the body. Within an appropriate gel, cells can attach to their surroundings, extend processes, migrate, and form three-dimensional structures. This type of 3D culture is possible even in standard culture dishes. The strength of microfluidics lies in combining a three-dimensional culture environment with precise fluid delivery and concentration control.

 

Observing the Growth of Nerves and Blood Vessels

In neuroscience research, the size and arrangement of channels serve as tools for distinguishing between observation targets. Neurons consist of a cell body containing the nucleus and extensions that transmit signals; among these, the axon is a long, slender structure that transmits signals to other cells. By creating a very narrow groove next to the space where the cell body is located, the cell body can be retained while the axon is guided to grow along the groove into the adjacent space. A microfluidic culture study published in 2005 demonstrated that this method allows for the separation and observation of axons and cell bodies, enabling the application of different stimuli to each.
This structure also aids in researching cell damage associated with Alzheimer’s disease. For example, it allows for the investigation of how amyloid beta, which is linked to the disease, affects neurons under specific conditions. In 2013, a joint research team from Korea University, Chung-Ang University, and the University of Michigan observed neuronal damage in a device that simulated slow fluid flow and a concentration gradient of amyloid beta. While such experiments provide a basis for understanding the toxicity of a substance and the damage process, the mere fact that axons were damaged in a culture device does not prove that the substance causes dementia in humans.
In vascular research, endothelial cells—which line the inside of blood vessels—and surrounding supporting cells are cultured together to examine how the cells connect and branch out within a gel. In 2013, a study was published describing the formation of a three-dimensional microvascular network within a microfluidic chip through which liquid could flow. Researchers can compare how the formation and function of the vascular network change by altering the distribution of growth factors or the types of surrounding cells. While the shape of the channels influences cell growth, it does not entirely determine the structure of a complex vascular network according to a blueprint. Interactions between cells and culture conditions also play a role.
This research leads to tissue engineering—the creation of tissue to repair or replace damaged tissue—as well as research on stem cells, which can differentiate into various cell types. In microfluidic devices, researchers can control the space where cells are placed and the substances supplied to them, allowing them to compare which conditions facilitate the formation of the desired tissue. However, even after culturing tissue into the desired shape, simply removing the gel does not mean it can be immediately transplanted into the human body. The gel may be necessary to support the tissue, and after implantation, factors such as blood supply, connection to surrounding tissues, immune response, and functional maintenance must be verified. There is a separate validation stage between creating tissue within a device and treating patients.

 

The Space Where Cells Live and the Pathways Through Which Culture Medium Flows

The structure of a microfluidic device varies depending on the experimental purpose. While some devices have only a single channel, a structure featuring a central gel region flanked by culture medium channels on either side is frequently used for three-dimensional cell culture. If you imagine looking down at it from above, it resembles a narrow garden where cells live, with waterways running along both sides. The bottom consists of a glass slide suitable for microscopic observation, and attached to it is a polymer structure forming microscopic channels.
A gel-forming solution mixed with cells is injected into the central region and allowed to gel under conditions suitable for the material. Subsequently, when culture medium is supplied to the channels on either side, nutrients and signaling molecules are delivered into the gel, while substances released by the cells move outward. Thus, the central gel region primarily serves as a three-dimensional support space where cells reside, while the side channels function as pathways for supplying and exchanging culture medium. If one simply views the structure as a mechanism to prevent drying by filling the side channels with water, one misses the core principle of cell culture.
Small columns may also be arranged in a row between the gel region and the culture medium channels. The reason the gel solution can be confined to a specific area even though the spaces between the columns are open is due to the combined effects of the liquid’s surface tension, the wettability of the surface, and the shape and spacing of the columns. By designing the system so that the liquid surface is held in place at the edges of the columns, the solution can be prevented from spreading into the adjacent channels before it solidifies. However, if the injection pressure is too high or the surface conditions are not appropriate, the solution may overflow; therefore, separation is not always maintained simply by having hydrophobic columns.
Once the gel has formed, water, nutrients, signaling molecules, and other substances pass through boundaries that are not completely sealed off by solid walls. This allows the delivery of substances necessary for the cells while maintaining the gel’s structure. Thanks to these open boundaries, researchers can also observe how cells inside the gel and those near the channels influence one another.

 

Methods for Creating Microscopic Channels in Transparent Polymers

One of the materials widely used in research-grade microfluidic devices is PDMS, or polydimethylsiloxane. PDMS is a transparent and flexible silicone-based polymer that is easy to fabricate into microstructures and allows gases such as oxygen to pass through. These characteristics are advantageous for observing the interior of the device under a microscope and for creating cell culture environments. However, just because the material is transparent does not mean that the entire observation process is harmless to the cells; cell survival is influenced not only by the material itself but also by lighting and culture conditions.
A key point to note when using PDMS is that its surface is inherently hydrophobic, meaning it does not readily absorb water. This distinguishes it from hydrophilic materials, which readily attract water. Oxygen plasma treatment can temporarily make the surface hydrophilic and is also useful for bonding it to glass. To attach cells to the surface, the material is sometimes coated with substances such as collagen or fibronectin. Additionally, PDMS can absorb certain hydrophobic drugs or small molecules into its interior, thereby altering the actual concentration of the culture medium. Therefore, it is more accurate to view PDMS as a material to be used with an understanding of its advantages and limitations, rather than as a material optimized for all cells and experiments.
A representative method for creating channels in PDMS is “soft lithography.” First, a light-sensitive photoresist material is applied to a flat substrate, such as a silicon wafer. Light is then exposed to the photoresist in the desired pattern, and after development, a circular mold with microscopic protrusions is created. A mixture of liquid PDMS and a curing agent is poured into this mold, allowed to harden, and then removed, leaving grooves in the PDMS that correspond to the protrusions of the mold. These grooves later serve as channels through which liquid flows.
Next, holes are created for filling and draining the liquid, and the channel-bearing surface is bonded tightly to a glass plate to complete the closed channel. After surface treatment and cell culture preparation appropriate for the experiment, the device is ready for use; flow is generated by differences in height between reservoirs or by pumps. A key advantage is the ability to repeatedly produce identical structures using a single circular mold. However, if the channels are too wide or too thin, they may deform or collapse; therefore, the design process does not end simply with sketching the desired shape.
In the design of these small devices, the shape of the channels, the surface properties of the materials, the flow of the liquid, and the conditions for cell survival are all interrelated. It is difficult to create a stable culture environment by adjusting just one of these factors. Microfluidics addresses these conditions collectively, allowing us to observe how cells grow, connect, and sustain damage in various environments. Just as people in movies enter the human body to explore life, in the laboratory, we create the environment in which cells live on a small chip to observe the workings of life.

 

About the author

Cam Tien

I love things that are gentle and cute. I love dogs, cats, and flowers because they make me happy. I also enjoy eating and traveling to discover new things. Besides that, I like to lie back, take in the scenery, and relax to enjoy life.